Sign on

SAO/NASA ADS Astronomy Abstract Service


· Find Similar Abstracts (with default settings below)
· Electronic Refereed Journal Article (HTML)
· Also-Read Articles (Reads History)
·
· Translate This Page
Title:
A 90GHz array for the Green Bank Telescope
Authors:
Benford, D. J.; Devlin (Pi), M. J.; Dicker, S. R.; Irwin, K. D.; Jewell, P. R.; Klein, J.; Mason, B. S.; Moseley, H. S.; Norrod, R. D.; Supanich, M. P.
Affiliation:
AA(Goddard Space Flight Center, Greenbelt, MD 20771, USA), AB(University of Pennsylvania, 209 S. 33rd st., Philadelphia, PA 19104, USA), AC(University of Pennsylvania, 209 S. 33rd st., Philadelphia, PA 19104, USA; ), AD(NIST electromagnetic technology division, 325 Broadway, Boulder, CO 80305-332, USA), AE(NRAO-Green Bank, PO.Box 2, Green Bank, WV 24944, USA), AF(University of Pennsylvania, 209 S. 33rd st., Philadelphia, PA 19104, USA), AG(NRAO-Green Bank, PO.Box 2, Green Bank, WV 24944, USA), AH(Goddard Space Flight Center, Greenbelt, MD 20771, USA), AI(NRAO-Green Bank, PO.Box 2, Green Bank, WV 24944, USA), AJ(University of Pennsylvania, 209 S. 33rd st., Philadelphia, PA 19104, USA)
Publication:
Nuclear Instruments and Methods in Physics Research Section A, Volume 520, Issue 1-3, p. 387-389.
Publication Date:
03/2004
Origin:
ELSEVIER
Keywords:
TES bolometer array, Millimeter wave receivers, Cryogenics
DOI:
10.1016/j.nima.2003.11.341
Bibliographic Code:
2004NIMPA.520..387B

Abstract

We report on the design and construction of an 8×8 bolometer array designed to operate at 90GHz on the new 100m Green Bank Telescope (GBT). The bolometers are Transition Edge Superconducting (TES) detectors read out using a SQUID multiplexing system. The receiver will be one of the first astronomical instruments to use such detectors. To cool the detectors, we have developed 3He and 4He sorption refrigerators that cycle from a two-stage pulse-tube cryocooler. The system has been demonstrated to be robust, to be capable of cycling autonomously, and to provide 15μW of cooling below 286mK with a hold time over 70h. Although modest in size, a combination of the size of GBT and the low noise of the TES detectors will make our receiver one of the most sensitive of its kind.
Bibtex entry for this abstract   Preferred format for this abstract (see Preferences)

   

Find Similar Abstracts:

Use: Authors
Title
Keywords (in text query field)
Abstract Text
Return: Query Results Return    items starting with number
Query Form
Database: Astronomy
Physics
arXiv e-prints