Sign on

SAO/NASA ADS Physics Abstract Service


· Find Similar Abstracts (with default settings below)
· Table of Contents
· Also-Read Articles (Reads History)
·
· Translate This Page
Title:
2.5-kHz magnetostrictive Tonpilz sonar transducer design
Authors:
Butler, Stephen C.
Affiliation:
AA(Naval Undersea Warfare Ctr.)
Publication:
Proc. SPIE Vol. 4699, p. 510-521, Smart Structures and Materials 2002: Active Materials: Behavior and Mechanics, Christopher S. Lynch; Ed. (SPIE Homepage)
Publication Date:
07/2002
Origin:
SPIE
Abstract Copyright:
(c) 2002 SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Bibliographic Code:
2002SPIE.4699..510B

Abstract

Naval Undersea Warfare Center has fabricated and tested a 2.5 kHz magnetostrictive sonar transducer to validate various modeling techniques. The transducer selected is a longitudinal vibrator Tonpilz type consisting of Terfenol-D driver, tail mass, radiating head mass, and stress rod bolt with 21 MPa (3000 psi) prestress. The Terfenol-D drive rod is interlaced with three samarium cobalt magnets, one in the center and one on either end magnetically biasing the Terfenol to 60 kA/m (750 Oe). Both the Terfenol-D rods and magnets were laminated to reduce eddy currents. The magnetic circuit is comprised of pole piece discs on each end of the Terfenol-D magnet assembly and an external magnetic cylinder (return path) made of a high-permeability, high-resistivity, high-saturation powdered metal 'T2'. The transducer has a 25 cm (9.8in) diameter radiating face (piston), is 28 cm (11 in.) long, and weighs 15 kg (32 lb.) without the housing. It is 41 cm (16 in.) long and 25 kg (56 lb.) with the underwater housing. The measured results are compared to a finite element model using 'ATILA' and distributed plane wave element equivalent circuit model. The coupling coefficient, permeability and mechanical loss effects for different prestress loads were measured on a resonant Terfenol 'dumbbell' device. The in-water measured results indicate a mechanical Q of 2.5, an effective coupling coefficient of 0.36, an electro-acoustic efficiency of 60 percent, beam pattern directivity index of 6 dB, a maximum Source Level of 214.6 dB re 1uPa/m at 15 Amps AC drive and bandwidth of 2 kHz to 5.4 kHz +/- 1.5 dB.
Bibtex entry for this abstract   Preferred format for this abstract (see Preferences)

   

Find Similar Abstracts:

Use: Authors
Title
Abstract Text
Return: Query Results Return    items starting with number
Query Form
Database: Astronomy
Physics
arXiv e-prints
    



SAO/NASA ADS Homepage | ADS Sitemap | Query Form | Basic Search | Preferences | HELP | FAQ