Title:
Optical coherence tomography technique for noninvasive blood glucose monitoring: phantom, animal, and human studies
Authors:
Larin, Kirill V.; Ashitkov, Taras V.; Larina, Irina V.; Petrova, Irina Y.; Eledrisi, Mohsen S.; Motamedi, Massoud; Esenaliev, Rinat O.
Affiliation:
AA(Univ. of Texas Medical Branch at Galveston)
Publication:
Proc. SPIE Vol. 4619, p. 157-164, Coherence Domain Optical Methods in Biomedical Science and Clinical Applications VI, Valery V. Tuchin; Joseph A. Izatt; James G. Fujimoto; Eds. (SPIE Homepage)
Publication Date:
06/2002
Origin:
SPIE
Abstract Copyright:
(c) 2002 SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Bibliographic Code:
2002SPIE.4619..157L

Abstract

Continuous noninvasive monitoring of blood glucose concentration can improve management of Diabetes Mellitus, reduce mortality, and considerably improve quality of life of diabetic patients. Recently, we proposed to use the OCT technique for noninvasive glucose monitoring. In this paper, we tested noninvasive blood glucose monitoring with the OCT technique in phantoms, animals, and human subjects. An OCT system with the wavelength of 1300 nm was used in our experiments. Phantom studies performed on aqueous suspensions of polystyrene microspheres and milk showed 3.2% decrease of exponential slope of OCT signals when glucose concentration increased from 0 to 100 mM. Theoretical calculations based on the Mie theory of scattering support the results obtained in phantoms. Bolus glucose injections and glucose clamping experiments were performed in animals (New Zealand rabbits and Yucatan micropigs). Good correlation between changes in the OCT signal slope and actual blood glucose concentration were observed in these experiments. First studies were performed in healthy human subjects (using oral glucose tolerance tests). Dependence of the slope of the OCT signals on the actual blood glucose concentration was similar to that obtained in animal studies. Our studies suggest that the OCT technique can potentially be used for noninvasive blood glucose monitoring.