Sign on

SAO/NASA ADS Astronomy Abstract Service


· Find Similar Abstracts (with default settings below)
· Electronic Refereed Journal Article (HTML)
· Full Refereed Journal Article (PDF/Postscript)
· References in the article
· Citations to the Article (31) (Citation History)
· Refereed Citations to the Article
· SIMBAD Objects (1)
· NED Objects (2)
· Also-Read Articles (Reads History)
·
· Translate This Page
Title:
The Detection of Highly Ionized Gas via O VI Absorption toward QSO HS 1422+2309
Authors:
Kirkman, David; Tytler, David
Publication:
Astrophysical Journal Letters v.489, p.L123 (ApJL Homepage)
Publication Date:
11/1997
Origin:
APJ
ApJ Keywords:
GALAXIES: QUASARS: ABSORPTION LINES
DOI:
10.1086/316781
Bibliographic Code:
1997ApJ...489L.123K

Abstract

We have detected O VI absorption in a Lyman limit system at z=3.3816 toward QSO HS 1422+2309. We have also detected C IV absorption, but we have not seen N V, Si IV, or C II. The line widths of O VI and C IV show that the kinetic temperature of the system is 10^4.5 < T < 10^5 K. The system may be collisionally ionized, because the O VI column density is larger than the C IV column density, the temperature is high, and because there may be few or no photons with energies greater than 4 ryd, which are needed to photoionize O VI. This is because the Ly alpha forest provides an optical depth of unity in a redshift path of 0.03, less than the typical distance to a bright QSO. If the gas is collisionally ionized with approximately cosmic abundance ratios, the C IV to O VI ratio gives an ionization temperature of T ~ 10^5.3 K, which is significantly higher than the kinetic temperature measured by the line widths, perhaps because the gas is out of thermal equilibrium and cooling rapidly, much like the coronal gas of our Galaxy. We have estimated the total hydrogen column density of this system using the observed O VI column together with an assumed metallicity of -2, and we have found that it is very large: N(H) = 10^20.6 cm-2 if the system is collisionally ionized, and 10^19.9 cm-2 if the system is photoionized. If most Lyman limit systems have a similar high-ionization component, and there is some evidence that they do, the mass density in hot and highly ionized gas would be large: Omega hot ~ 0.4 Omega b ( h=0.7 ), ~10 times more than in the cold neutral gas seen in damped Ly alpha systems.
Bibtex entry for this abstract   Preferred format for this abstract (see Preferences)

   

Find Similar Abstracts:

Use: Authors
Title
Keywords (in text query field)
Abstract Text
Return: Query Results Return    items starting with number
Query Form
Database: Astronomy
Physics
arXiv e-prints