Sign on

SAO/NASA ADS General Science Abstract Service


· Find Similar Abstracts (with default settings below)
· Electronic Refereed Journal Article (HTML)
· References in the article
· Citations to the Article (1) (Citation History)
· Refereed Citations to the Article
· Also-Read Articles (Reads History)
·
· Translate This Page
Title:
Gamma dosimetry at surfaces of cylindrical containers
Authors:
Pattison, John E.; Bachmann, Darren J.; Beddoe, Alun H.
Affiliation:
AA(School of Physics and Electronic Systems Engineering, University of South Australia, The Levels, South Australia, Australia, 5095 ; Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia, Australia, 5000 ), AB(School of Physics and Electronic Systems Engineering, University of South Australia, The Levels, South Australia, Australia, 5095 ; Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia, Australia, 5000 ), AC(Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia, Australia, 5000 ; Medical Physics Service, Queen Elizabeth Hospital, Birmingham B15 2TH, UK)
Publication:
Journal of Radiological Protection, Volume 16, Issue 4, pp. 249-261 (1996).
Publication Date:
12/1996
Origin:
IOP
DOI:
10.1088/0952-4746/16/4/004
Bibliographic Code:
1996JRP....16..249P

Abstract

Gamma-ray dose rates on the exterior surfaces of cylindrical vessels containing radioactive solutions are calculated using a model based on the distributed point source approximation. A cylinder is subdivided into a number of annular sector segments of equal volume and the dose rate from each segment is combined to give the total dose rate at a point on the exterior surface of the cylindrical container. Calculated results for the method are compared with experimentally determined results for (a pure -emitter) and (a mixed and -emitter) in acrylic containers of various wall thicknesses, as well as for single containers made from polycarbonate and polypropylene; good agreement was obtained. Calculated results for the -ray dose rates to the skin of the fingers, for partially filled plastic syringes, are compared with other published results, for , , , , and in syringes of various diameters and wall thicknesses; good agreement was obtained. The calculations are extended to provide results for the -ray dose rate distribution along the external surfaces of partially filled syringes for and . These results are used to objectively derive guidelines for the safe handling of cylindrical vessels containing -emitting radionuclides, without the use of extra shielding. It was found that the weekly dose limit to the skin, of 10 mSv, is exceeded if the fingers are in contact with the container, over the active volume, for periods greater than about one minute. However, if handled at the rear of the syringe barrel a typical weekly work load can be managed without exceeding dose limits. It is recommended, when using syringes without syringe guards, that the fingers should never approach the active volume closer than the rear end of the syringe barrel, and that syringes should not be filled beyond 75% of their capacity.
Bibtex entry for this abstract   Preferred format for this abstract (see Preferences)


Find Similar Abstracts:

Use: Authors
Title
Abstract Text
Return: Query Results Return    items starting with number
Query Form
Database: Astronomy
Physics
arXiv e-prints